Paramtents
Fiber Type G652D,G657A1,G657A2
Fiber Count 1-12 cores
OEM Available
Packging & Delivery
Min Order1 kilometer
Briefing
Detailed
1.2 Feature
A. Flexible, high compressive property, excellent wear and corrosion resistance, good oil resistance;
B. Good mechanical and environmental characteristic, wide operating temperature range;
C. Meet the requirements of RoHS requirements
1.3 Application
A. The end of the cable can be processed into fiber connector, suitable for indoor and outdoor environment;
B. Used in temperature measurement of tunnel fire fighting or industrial environment;
C. Used in physical examination of building such as bridge, warehouse, etc
1.4 CableProperties
Transporttemperature: - 20 deg C to + 60 deg C
Storage Temperature: - 20 deg C to + 60 deg C
Operating temperature: - 20 deg C to + 60 deg C
Installation temperature: - 5 deg C to + 50 deg C
2. Optical Characteristics& Technical Parameters
2.1 Technical Parameters
Cable Code
|
Cable Diameter
mm |
Cable Weight(Ref) kg/km | TBF Diameter μm | Tensile strength Long/Short term mm |
Crush Resistance
Long/short term N/100mm |
Bending Radius
Dynamic/Static mm |
|
PVC jacket | LSZH jacket |
||||||
GJSFJH
|
Customized
|
8.0-25 | 10.0-50 | 600/900 | 300/600 |
500/1000
|
60/30
|
Fiber Type |
Attenuation |
OFL | Valid mode band width |
10G Ethernet link length SX |
Min. bending radius | |||
Condition | 1310/1550nm | 850/1300nm |
850/1300nm | 850nm | 850nm | |||
Typical
|
Max. | Typical | Max. |
|
|
|||
Unit
|
dB/km
|
dB/km | dB/km | dB/km | MHZ.km |
MHZ.km
|
m
|
mm |
G652D | 0.36/0.22 | 0.5/0.4 | 16 | |||||
G657A1 | 0.36/0.22 | 0.5/0.4 | 10 | |||||
G657A2 | 0.36/0.22 | 0.5/0.4 | 7.5 | |||||
OM1 | 3.0/1.0 | 3.5/1.5 | ≥500/500 | ≥2000 | ≤300 | 30 | ||
OM2 | 3.0/1.0 | 3.5/1.5 | ≥200/500 | ≥4700 | ≤550 | 30 | ||
OM3 | 3.0/1.0 | 3.5/1.5 | ≥1500/500 | ≥2000 | ≤300 | 30 | ||
OM4 | 3.0/1.0 | 3.5/1.5 | ≥3500/500 | ≥4700 | ≤350 | 30 |
3. Packing and shipping
3.1 The cables are packed in wooden drums andthen in carton box
3.2 Standard delivery length is 1km/roll or percustomer’s requirements.
3.3 Sheath Marking
The sheath marking are hotstamped on the sheath at one meter interval with white color. The accuracy ofthe length marking shall be 0 ~ +1%.
Re-marking is yellow color, ifnecessary.
RUX *** xxFIBRE Month/Year XXXXM
l RUX: Manufacturer’s Name
l ***: Customer’s name
l xxFIBRE: Fiber count
l Month/Year: Manufacturedate
l XXXXM: The figure of meter.